ANDRITZ Hydro business division key visual

Bulb Turbines Technology - Fit for the Future

When Austrian professor Viktor Kaplan (1876 –1934) filed his essential patents for the eponymous turbine in 1912 and 1913, he opened the way for a new technology able to use low hydrostatic heads for power generation in an economically feasible way - especially at run-of-river plants.

Bulb turbine runner during installation process at HPP Iffezheim, Germany

Bulb turbine runner during installation process at HPP Iffezheim, Germany

In particular, the horizontal type of Kaplan machine - the Bulb turbine - shows extraordinary flexibility in its application. From small to large, from run-of-river to tidal, and from fixed to variable-speed everything is possible within a head range of 0.5 up to 30 meters.

However, new market needs have meant reconsidering several basic de­-sign principles. For example, having ecologically, as well as economically, feasible solutions is becoming an ever greater consideration in the planning and approval process for hydropower projects.

Furthermore, new requirements for grid control have motivated energy producers to switch Bulb and Kaplan turbines - which were formerly operated in level control - to primary control in order to provide grid frequency stabilization services.

In addition, the intention to utilize tidal forces as renewable and clean energy resource has triggered new concepts concerning hydraulic as well as mecha­n­ical design and the extended application of sophisticated, stainless materials.

The worldwide leader in Bulb turbine units - with a total installed capacity of approximately 6,500 MW and covering a market share of more than 70% - ANDRITZ HYDRO focused its research and development efforts on these new demands at an early stage.

Schematic 3D-drawing of Bulb turbine for HPP Iffezheim, Germany

Schematic 3D-drawing of Bulb turbine for HPP Iffezheim, Germany

Demanding environmental performance

Increasing demands for ecological performance have prompted changes in the use of problematic substances, such as lubricating oils, while the impact hydropower stations have on aquatic life has become a major issue for new and the refurbishment of existing hydraulic turbines.

The development of oil-free solutions for Bulb turbine runners was initiated many years ago and ANDRITZ HYDRO has recorded more than 130 references within the last 20 years for oil-free Kaplan runners up to largest diameters, outputs and heads in the Kaplan range - always offering the best solutions.

Instead of oil, the hub is filled with water together with a corrosion inhibitor similar to the citric acid found in lemons and which is non-toxic and not hazardous.

Blade bearings also represent a key element in realizing an oil-free runner hub. Extensive testing has been performed in order to determine the best solutions for bearing materials. The result is a comprehensive database comprising coefficients of friction, wear and allowable pressures. Based on that, the best material can be selected for each application.

ANDRITZ HYDRO also invests in the research and development of fish-friendly turbine technology. In order to reduce damage to the fish population – as well as avoiding damage to the turbines - many theoretical approaches and computation models have been developed over the years. By combining hydraulic knowledge with biological understanding, ANDRITZ HYDRO is able to minimize fish injury without major energy losses.

Changing control requirements

Switching turbine regulation from level control to primary control introduces a significant change in the frequency of regulation movements by the runner and the guide vane mechanisms. More regulation movements result in more load cycles for the affected parts.

Records from one unit operating in these two different modes show a significant increase in load-cycles for the differential pressure of the runner servomotor actuating the blade movements during primary control, when compared with discharge control operation.

More load cycles inevitably make fatigue a greater consideration. Fatigue is influenced by the material, the geometry of the parts and the cyclic loading. In a Bulb turbine the blade is affected by centrifugal force, axial thrust and circumferential force as well as hydraulic torque from the pressure distribution on the blade.

Faced with changing operational demands ANDRITZ HYDRO has developed tools to accurately assess the impact of changing operational requirements on fatigue - as well as other considerations - and can therefore support energy producers in the diagnosis and assessment of the residual service life of turbine equipment.

Installation of Compact Bulb turbine at HPP Gstatterboden, Austria

Installation of Compact Bulb turbine at HPP Gstatterboden, Austria

Tidal applications

ANDRITZ HYDRO has also developed a sound and leading technology in the tidal barrage field, starting with the Annapolis tidal plant in Canada back in 1984. Technical development continued with the Shiwa tidal plant in South Korea in 2004, and improved further during the on-going design of the units for the Swansea Bay Lagoon tidal plant in Great Britain.

Tidal energy can be used in two ways - by utilizing the potential energy of the tidal lift or the kinetic energy of the tidal stream. Both can be realized with horizontal Kaplan turbines of differing design and the push to extract energy from the tides has also prompted technical innovations.

For instance, the large head variations found during a tidal cycle initiated the intro­duction of variable-speed technologies which, in addition to movable guide vanes and runner blades, lead to triple-regulated machines.

ANDRITZ HYDRO Hammerfest was and is a pioneer in tidal current technology. The tidal flow turbine concept was developed in 1997; the first 300 kW prototype was installed in 2003; a 1 MW unit followed in 2011 and the first commercial array – with 265 units in total - will be started with four 1.5 MW demonstration units in 2016.

Viktor Kaplan’s idea may have emerged more than a century ago, but in light of changing environmental, economic and operational needs ANDRITZ HYDRO strives to ensure that his ingenious basic idea for a low head and efficient turbine is further developed in order to fulfill today’s demanding requirements and to make his legacy FIT FOR THE FUTURE.

TECHNICAL DATA  

Gstatterboden, Austria: 
Output1×1.2 MW
Head9.5 m
Speed250 rpm
Runner diameter1,950 mm
Iffezheim, Germany: 
Output1 × 38.5 MW
Head9.5 m
Speed83.3 rpm
Runner diameter6,800 mm
Santo Antônio, Brazil: 
5-blade turbine6 × 71.05 MW
4-blade turbine6 × 74.8 MW
Generator12 × 82.25 MVA
Speed100 rpm
Runner diameter7,500 mm
Sihwa Tidal, South Korea: 
Output10 × 26 MW
Head2–9.8 m
Speed64.3 rpm
Runner diameter7,500 mm

 

Installation works for a small Bulb turbine

Installation works for a small Bulb turbine

Contact us
HYDRO News Editorial Office
Eibesbrunnergasse 20
1120 Vienna
Downloads
  • hy-hn29-en.pdf
    HYDRO NEWS Issue 29 PDF : 8.4 MB
  • Article as PDF PDF : 1.7 MB